Wash. Admin. Code § 51-11C-610211 - Table A102.1 - Default U-factors for ceilings

Table A102.1 Default U-factors for Ceilings

Standard Frame

Advanced Frame

Ceilings Below Vented Attics

Flat

Baffled

R-19

0.049

0.047

R-30

0.036

0.032

R-38

0.031

0.026

R-49

0.027

0.020

R-60

0.025

0.017

Scissors Truss

R-30 (4/12 roof pitch)

0.043

0.031

R-38 (4/12 roof pitch)

0.040

0.025

R-49 (4/12 roof pitch)

0.038

0.020

R-30 (5/12 roof pitch)

0.039

0.032

R-38 (5/12 roof pitch)

0.035

0.026

R-49 (5/12 roof pitch)

0.032

0.020

Vaulted Ceilings

16" O.C.

24" O.C.

Vented

R-19 2x10 joist

0.049

0.048

R-30 2x12 joist

0.034

0.033

R-38 2x14 joist

0.027

0.027

Unvented

R-30 2x10 joist

0.034

0.033

R-38 2x12 joist

0.029

0.027

R-21 + R-21 2x12 joist

0.026

0.025

Roof Deck

4 x Beams, 48" O.C.

R-12.5

2"

Rigid insulation

0.064

R-21.9

3.5"

Rigid insulation

0.040

R-37.5

6"

Rigid insulation

0.025

R-50

8"

Rigid insulation

0.019