Wash. Admin. Code § 51-11C-610332 - Section A103.3.2 - Strap wall
A103.3.2 Strap wall. Table A103.3.2: Assumes 2 x 6 studs framed on 16 or 24 inch centers. 2 x 3 or 2 x 4 strapping is run horizontally along the interior surface of the wall to provide additional space for insulation.
Table A103.3.2 2 x 6: Strap Wall
Siding Material/Frame Type |
||||
Lapped Wood |
T1-11 |
|||
STD |
ADV |
STD |
ADV |
|
R-19 + R-11 Batts |
0.036 |
0.035 |
0.038 |
0.036 |
R-19 + R-8 Batts |
0.041 |
0.039 |
0.042 |
0.040 |
Notes
Statutory Authority: RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. 13-04-056, § 51-11C-610332, filed 2/1/13, effective 7/1/13.