W. Va. Code R. § 103-7-19 - Heating
19.1. The home
inspector shall inspect permanently installed heating systems including:
19.1.a. Heating equipment;
19.1.b. Normal operating controls;
19.1.c. Automatic safety controls;
19.1.d. Chimney, flues and vents, where
readily visible;
19.1.e. Solid fuel
heating devices including fireplaces;
19.1.f. Heat distribution systems including
fans, pumps, ducts, and piping, with associated supports, insulation, air
filters, registers, radiators, fan coil units, convectors; and
19.1.g. The presence of an installed heat
source in each room.
19.2. The home inspector shall describe:
19.2.a. The energy source; and
19.2.b. The heating equipment and
distribution type.
19.3.
The home inspector shall operate the systems using normal operating
controls.
19.4. The home inspector
shall open readily accessible panels provided by the manufacturer or installer
for routine homeowner maintenance.
19.5. The home inspector is not required to:
19.5.a. Operate heating systems when weather
conditions or other circumstances may cause equipment damage;
19.5.b. Operate automatic safety
controls;
19.5.c. Ignite or
extinguish solid fuel fires and/or pilot lights; or
19.5.d. Inspect:
19.5.d.1. The interior of flues;
19.5.d.2. Fireplace insert flue
connections;
19.5.d.3.
Humidifiers;
19.5.d.4. Electronic
air filters; or
19.5.d.5. The
uniformity or adequacy of heat supplies to the various rooms.