W. Va. Code R. § 36-23-24 - Temporary Heating Devices
24.1.
(a) Ventilation.
(1) Fresh air shall be supplied in sufficient
quantities to maintain the health and safety of workmen. Where natural means of
fresh air supply is inadequate, mechanical ventilation shall be
provided.
(2) When heaters are used
in confined spaces, special care shall be taken to provide sufficient
ventilation in order to ensure proper combustion, maintain the health and
safety of workmen, and limit temperature rise in the area.
(b) Clearance and mounting.
(1) Temporary heating devices shall be
installed to provide clearance to combustible material not less than
the amount shown in Table 3, may be installed in accordance with their
approval.
(2) Temporary heating
devices, which are listed for installation with lesser clearances than
specified in Table 3, may be installed in accordance with their
approval.
(3) Heaters not suitable
for use on wood floors shall not be set directly upon them or other combustible
materials. When such heaters are used, they shall rest on suitable heat
insulating material or at least one (1) inch concrete, or equivalent. The
insulating material shall extend beyond the heater two (2) feet or more in all
directions.
(4) Heaters used in the
vicinity of combustible tarpaulins, canvas, or similar coverings shall
be located at least ten (10) feet from the coverings.
The coverings shall be securely fastened to prevent ignition or upsetting of the heater due to wind action on the covering or other material.
(c)
Stability. Heaters, when in use, shall be set horizontally level,
unless otherwise permitted by the manufacturer's markings.
(d) Solid fuel salamanders. Solid fuel
salamanders are prohibited in buildings and on scaffolds.
(e) Oil-fired heaters.
(1) Flammable liquid-fired heaters shall be
equipped with a primary safety control to stop the flow of fuel in the event of
flame failure. Barometric or gravity oil feed shall not be considered a primary
safety control.
(2) Heaters
designed for barometric or gravity oil feed shall be used only with the
integral tanks.
(3) Heaters
specifically designed and approved for use with separate supply tanks may be
directly connected for gravity feed, or an automatic pump, from a supply
tank.
24.2.
Definitions applicable to this subpart.
(a) "Approved" for the purpose of this
subpart, means equipment that has been listed or approved by a nationally
recognized testing laboratory such as Factory Mutual Engineering
Corporation, or Underwriters Laboratories
Incorporated, or federal agencies such as Bureau of Mines, or United States Coast Guard, which issues approvals for such equipment.
(b)
"Closed Container" means a container so sealed by means of a lid or
other device that neither liquid nor vapor will escape from it at ordinary
temperatures.
(c) "Combustible
Liquids" means any liquid having a flash point at or above one hundred forty
degrees (140 degrees) F. (sixty (60) degrees C.), and below two hundred (200)
degrees F. (ninety three point four (93.4) degrees C.).
(d) "Combustion" means any chemical process
that involves oxidation sufficient to produce light or heat.
(e) "Fire Resistance" means so
resistant to fire that, for specified time and under conditions of a
standard heat intensity, it will not fall structurally and will not permit the
side away from the fire to become hotter than a specified temperature. For
purposes of this part, fire resistance shall be determined by the standard
Methods of Fire Tests of Building Construction and Materials, NFPA
251-1969.
(f) "Flammable" means
capable of being easily ignited, burning intensely, or having a rapid rate of
flame spread.
(g) "Flammable
Liquids" means any liquid having a flash point below one hundred forty (140)
degrees F. and having a vapor pressure not exceeding forty (40) pounds per
square inch (absolute) at one hundred (100) degrees F.
(h) "Flash Point" of the liquid means the
temperature at which it gives off vapor sufficient to form an ignitable mixture
with the air near the surface of the liquid or within the vessel used as
determined by appropriate test procedure and apparatus as specified below.
(1) The flash point of liquids having a
viscosity less than forty-five (45) Saybolt Universal Second at one hundred
(100) degrees F. (thirty seven point eight (37.8) degrees C.) and a flash point
below one hundred seventy-five (175) degrees F. (seventy nine point
four (79.4) degrees C.) shall be determined in accordance with the standard
method of Test for Flash Point by the Tage Closed Tester, ASTM
D-56-69.
(2) The flash point of
liquids having a viscosity of forty-five Saybolt Universal Second(s) or
more than one hundred seventy-five (175) degrees F. (seventy nine point four
(79.4) degrees C.) or higher shall be determined in accordance with the
standard method of test for Flash Point by the Pensky Martens Closed Tester,
ASTM D-93-69.
(i)
"Portable tank" means a closed container having a liquid capacity more than
sixty (60) United States gallons, and not intended for fixed
installation.
(j) "Safety Can"
means an approved metal container, of not more than five (5) gallons capacity,
having a flash-arresting screen, spring-closing lid and spout cover and so
designed that it will safely relieve internal pressure when subjected to fire
exposure.
(k) "Vapor Pressure"
means the pressure, measured in pounds per square inch (absolute),
exerted by a volatile liquid, as determined by the standard method of test for
Vapor Pressure of Petroleum Products (Reid Method). (ASTM D-323-58.)