40.1. General provisions.
(a) After the effective date of the certified
surface blasters rules and regulations, all persons performing blasting
operations on construction projects shall be certified. The employer shall
permit only authorized and qualified persons to handle and use
explosives.
(b) Smoking, firearms,
matches, open flame lamps, and other fires, flame or heat producing devices and
sparks shall be prohibited in or near explosive magazines or while
explosives are being handled, transported or used.
(c) No person shall be allowed to handle or
use explosives while under the influence of intoxicating liquors, narcotics, or
other dangerous drugs.
(d) All
explosives shall be accounted for at all times. Explosives not being used shall
be kept in a locked magazine, unavailable to persons not authorized to handle
them. The employer shall maintain an inventory and use records of all
explosives. Appropriate authorities shall be notified of any loss,
theft, or unauthorized entry into a magazine.
(e) No explosives or blasting agents shall be
abandoned.
(f) No fire shall be
fought where the fire is in imminent danger of contact with explosives. All
employees shall be removed to a safe area and the fire area guarded against
intruders.
(g) Original containers,
or Class 2 magazine, shall be used for taking detonators and other explosives
from storage magazines to the blasting area.
(h) When blasting is done in
congested areas or in proximity to a structure, railway, or
highway, or any other installation that may be damaged, the blaster shall take
special precautions in the loading, delaying, initiation, and confinement of
each blast with mats or other methods so as to control the throw of fragments,
and thus prevent bodily injury to employees.
(i) Employees authorized to prepare explosive
charges or conduct blasting operations shall use every reasonable
precaution including, but not limited to visual and audible warning signals,
flags, or barricades, to ensure employee safety.
(j) Insofar as possible, blasting
operations above ground shall be conducted between sunup and
sundown.
(k) Due precautions shall
be taken to prevent accidental discharge of electric blasting caps from
current induced by radar, radio transmitters, lightning, adjacent power lines,
dust storms, or other sources of extraneous electricity. These precautions
shall include:
(1) Detonators shall be
short-circuited in holes which have been primed and shunted until wired
into the blasting circuit;
(2) The
suspension of all blasting operations and removal of persons from the blasting
area during the approach and progress of an electric storm;
(3)
(i) The
prominent display of adequate signs, warning against the use of mobile radio
transmitters, on all roads within one thousand (1,000) feet of blasting
operations. Whenever adherence to the one thousand (1,000) foot
distance would create an operational handicap, a competent person shall be
consulted to evaluate the particular situation, and alternative
provisions may be made which are adequately designed to prevent any premature
firing of electric blasting caps. A description of any such alternatives shall
be reduced to writing and shall be certified as meeting the purposes of this
subdivision by the competent person consulted. The description shall be
maintained at the construction site during the duration of the work and shall
be available for inspection by representatives of the Secretary of
Labor.
(ii) Specimens of signs
which would meet the requirements of subdivision (i) of this
subparagraph (3) are the following (See Table 49):
(4) Ensuring that mobile radio transmitters
which are less than one hundred (100) feet away from electric blasting caps, in
other than original containers shall be deenergized and effectively
locked.
(5) Compliance with the
recommendations of the Institute of the Makers of Explosives with
regard to blasting in the vicinity of radio transmitters as stipulated
in radio frequency energy-a potential hazard in the use of electric blasting
caps, IME publication No. 20, March, 1971.
(l) Empty boxes and paper and fiber packing
materials, which have previously contained high explosives, shall not be used
again for any purpose, but shall be destroyed by burning at an approved
location.
(m) Explosives, blasting
agents, and blasting supplies that are obviously deteriorated or
damaged shall not be used.
(n)
Delivery and issue of explosives shall only be made by and to authorized
persons and into authorized magazines or approved temporary
storage or handling areas.
(o)
Blasting operations in the proximity of overhead power lines,
communication lines, utility services, or other services and structures shall
not be carried on until the operators and/or owners have been notified and
measures for safe control have been taken.
(p) The use of black powder shall be
prohibited.
(q) All loading and
firing shall be directed and directly supervised by a competent persons
thorough experienced in this field.
(r) All blasts shall be fired electrically
with an electric blasting machine or properly designed electric power source,
except as provided in paragraphs (a) and (p) of Section 40.8 of these
regulations.
40.2.
Explosives and blasting agents.
(a) Buildings
used for the mixing of blasting agents shall conform to the
requirements of this section.
(b) Buildings shall be of
noncombustible construction or sheet metal on wood studs.
(c) Floors in a mixing plant shall be of
concrete or other nonabsorbent materials.
(d) All fuel oil storage facilities shall be
separated from the mixing plant and located in such a manner that in case of
tank rupture, the oil will drain away from the mixing plant building.
(e) The building shall be well
ventilated.
(f) Heating
units which do not depend on combustion processes, when
properly designed and located, may be used in the building. All direct sources
of heat shall be provided exclusively from units located outside the mixing
building.
(g) All
internal-combustion engines used for electric power generation shall be located
outside the mixing plant building, or shall be properly ventilated and isolated
by a fire wall. The exhaust systems on all such engines shall be located so any
spark emission cannot be a hazard to any materials in or adjacent to the
plant.
(h) Buildings used for the
mixing of water gels shall conform to the requirements of this
subdivision.
(i) Buildings shall be
of noncombustible construction or sheet metal on wood stubs.
(j) Floors in a mixing plant shall be of
concrete or of other nonabsorbent materials.
(k) Where fuel oil is used all fuel oil
storage facilities shall be separated from the mixing plant and located in such
a manner that in case of tank rupture, the oil will drain away from the mixing
plant building.
(l) The building
shall be well ventilated.
(m) Heating units that do not depend on
combustion processes, when properly designed and located, may be used
in the building. All direct sources of heat shall be provided
exclusively from units located outside of the mixing building.
(n) All internal-combustion engines used for
electric power generation shall be located outside the mixing plant building,
or shall be properly ventilated and isolated by a fire wall. the exhaust
systems on all such engines shall be located so any spark emission cannot be a
hazard to any materials in or adjacent to the plant.
40.3. Blaster qualifications.
(a) A blaster shall be able to
understand and given written and oral orders.
(b) A blaster shall be in good physical
condition and not be addicted to narcotics, intoxicants, or similar types of
drugs.
(c) A blaster shall be
qualified, by training, knowledge, and experience, in the field of
transporting, storing, handling, and use of explosives, and have a working
knowledge of State and local laws and regulations which pertain to
explosives.
(d) Blasters shall be
required to furnish satisfactory evidence of competency in handling
explosives and performing in a safe manner the type of blasting that will be
required.
(e) The blaster
shall be knowledgeable and competent in the use of each type of blasting method
used.
40.4. Surface
transportation of explosives.
(a)
Transportation of explosives shall meet the provisions of the department of
transportation's regulations contained in 14 CFR Part
103, air
transportation; 46 CFR Parts
146-
149, water carriers; 49 CFR Parts
171-
179,
highways and railways; 49 CFR Part
180, pipelines; and 49 CFR Parts
390-
397,
motor carriers. Motor vehicles or conveyances transporting explosives shall
only be driven by, and be in charge of, a licensed driver who is physically
fit. He shall be familiar with the local, State, and federal regulations
governing the transportation of explosives.
(b) No person shall smoke, or carry matches
or any other flame-producing device, nor shall firearms or loaded cartridges be
carried while in or near a motor vehicle or conveyance transporting
explosives.
(c) Explosives,
blasting agents, and blasting supplies shall not be transported with other
materials or cargoes. Blasting caps (including electric) shall not be
transported in the same vehicle with other explosives.
(d) Vehicles used for transporting explosives
shall be strong enough to carry the load without difficulty, and shall be in
good mechanical condition.
(e) When
explosives are transported by a vehicle with an open body, a Class 2 magazine
or original manufacturer's container shall be securely mounted on the bed to
contain the cargo.
(f) All
vehicles used for the transportation of explosives shall have tight
floors and any exposed spark-producing metal on the inside of the body shall be
covered with wood, or other nonsparking material, to prevent contact with
containers of explosives.
(g) Every
motor vehicle or conveyance used for transporting explosives shall be
marked or placarded on both sides, the front, and the rear with the work
"Explosives" in red letters, not less than four (4) inches in height, in white
background. In addition to such marking or placarding, the motor vehicle or
conveyance may display, in such a manner that it will be readily visible from
all directions, a red flag eighteen (18) inches x thirty (30) inches, with the
word "Explosives" painted, stamped, or sewed thereon, in white letters, at
least six (6) inches in height.
(h)
Each vehicle used for transportation of explosives shall be equipped
with a fully charged fire extinguisher, in good condition. An approved
extinguisher of not less than ten (10) ABC rating will meet the minimum
requirement. The driver shall be trained in the use of the extinguisher on his
vehicle.
(i) Motor vehicles or
conveyances carrying explosives, blasting agents, or blasting supplies, shall
not be taken inside a garage or shop for repairs or servicing.
(j) No motor vehicle transporting explosives
shall be left unattended.
40.5. Storage of explosives and blasting
agents.
(a) Explosives and related materials
shall be stored in approved facilities required under the applicable provisions
of the internal revenue service regulations contained in 26 CFR
181, commerce
in explosives.
(b) Blasting caps,
electric blasting caps, detonating primers, and primed cartridges shall
not be stored in the same magazine with other explosives or blasting
agents.
(c) Smoking and open flames
shall not be permitted within fifty (50) feet of explosives and
detonator storage magazines.
40.6. Loading of explosives or blasting
agents.
(a) Procedures that permit safe and
efficient loading shall be established before loading is started.
(b) All drill holes shall be sufficiently
large to admit freely the insertion of the cartridges of explosives.
(c) Tamping shall be done only with wood rods
or plastic tamping poles without exposed metal parts, but nonsparking metal
connectors may be used for jointed poles. Violent tamping shall be avoided. The
primer shall never be tamped.
(d)
No holes shall be loaded except those to be fired in the next round of
blasting. After loading, all remaining explosives and detonators shall be
immediately returned to an authorized magazine.
(e) Drilling shall not be started until all
remaining butts of old holes are examined for unexploded charges, and if any
are found, they shall be refired before work proceeds.
(f) No person shall be allowed to deepen
drill holes which have contained explosives or blasting
agents.
(g) No explosives or
blasting agents shall be left unattended at the blast site.
(h) machines and all tools not used for
loading explosives into bore holes shall be removed from the immediate location
of holes before explosives are delivered. Equipment shall not be operated
within fifty (50) feet of loaded holes.
(i) No activity of any nature other than that
which is required for loading holes with explosives shall be permitted in a
blast area.
(j) Power lines and
portable electric cables for equipment being used shall be kept a safe distance
from explosives or blasting agents being loaded into drill holes. Cables in the
proximity of the blast area shall be deenergized and locked out by the
blaster.
(k) Holes shall be checked
prior to loading to determine depth and conditions. Where a hole has been
loaded with explosives but the explosives have failed to detonate, there shall
be no drilling within fifty (50) feet of the hole.
(l) When loading a long line of holes with
more than one (1) loading crew, the crews shall be separated by practical
distance consistent with efficient operation and supervision of
crews.
(m) No explosives shall be
loaded or used underground in the presence of combustible gases or
combustible dusts.
(n) No
explosives other than those in fume Class 1 shall be used; however,
explosives complying with the requirements of fume Class 2 and fume
Class 3 may be used if adequate ventilation has been
provided.
(o) All blast holes in
openwork shall be stemmed to the collar or to a point which will confine the
charge.
(p) Warning signs,
indicating a blast area, shall be maintained at all approaches to the blast
area. The warning sign lettering shall be not less than four (4) inches in
height on a contrasting background.
(q) A bore hole shall never be sprung when it
is adjacent to or near a hole that is loaded. Flashlight batteries shall not be
used for springing holes.
(r) Drill
holes which have been sprung or chambered, and which are not water filled,
shall be allowed to cool before explosives are loaded.
(s) No loaded holes shall be left unattended
or unprotected.
(t) The blaster
shall keep an accurate, up-to-date record of explosives, blasting agents, and
blasting supplies used in a blast and shall keep an accurate running inventory
of all explosives and blasting agents stored on the operation.
40.7. Explosives and
blasting agents.
(a) Semiconductive hose.
Semiconductive hose a hose with an electrical resistance high enough to
limit flow of stray electric currents to safe levels, yet not so high as to
prevent drainage of static electric charges to ground; hose of not more than
two (2) megohms resistance over its length and of not less than five thousand
(5,000) ohms per floor meets the requirements.
(b) When loading blasting agents
pneumatically over electric blasting caps, semiconductive delivery hose shall
be used and the equipment shall be bonded and grounded.
40.8. Initiation of explosive
charges--electric blasting.
(a)
Electric blasting caps shall not be used where sources of extraneous
electricity make the use of electric blasting caps dangerous. Blasting
cap leg wires shall be kept short-circuited (shunted) until they are
connected into the circuit for firing.
(b) Before adopting any system of electrical
firing, the blaster shall conduct a thorough survey for extraneous currents,
and all dangerous currents shall be eliminated before any holes are
loaded.
(c) In any single blast
using electric blasting caps, all caps shall be of the same style or function,
and of the same manufacture.
(d)
Electric blasting shall be carried out by using blasting circuits or power
circuits in accordance with the electric blasting cap manufacturer's
recommendations, or an approved contractor or his designated
representative.
(e) When
firing a circuit of electric blasting caps, care must be exercised to ensure
that an adequate quantity of delivered current is available, in accordance with
the manufacturer's recommendations.
(f) Connecting wires and lead wires shall be
insulated single solid wires of sufficient current-carrying
capacity.
(g) Bus wires shall be
solid single wires of sufficient current-carrying capacity.
(h) When firing electrically, the insulation
on all firing lines shall be adequate and in good condition.
(i) A power circuit used for firing electric
blasting caps shall not be grounded.
(j) When firing from a power circuit, the
firing switch shall be locked in the open or "Off" position at all times,
except when firing. It shall be so designed that the firing lines to the cap
circuit are automatically shortcircuited when the switch is in the
"Off" position. Keys to this switch shall be entrusted only to the
blaster.
(k) Blasting machines
shall be in good condition and the efficiency of the machine shall be tested
periodically to make certain that it can deliver power at its rated
capacity.
(l) When firing with
blasting machines, the connections shall be made as recommended
by the manufacturer of the electric blasting caps used.
(m) the number of electric blasting caps
connected to a blasting machine shall not be in excess of its rated capacity.
furthermore, in primary blasting, a series circuit shall contain no
more caps than the limits recommended by the manufacturer of the electric
blasting caps in use.
(n) The
blaster shall be in charge of the blasting machines, and no other person shall
connect the leading wires to the machine.
(o) Blasters, when testing circuits to
charged holes, shall use only blasting galvanometers equipped with a
silver chloride cell especially designed for this purpose.
(p) Whenever the possibility exists that a
leading line or blasting wire might be thrown over a live power line by the
force of an explosion, care shall be taken to see that the total length of
wires are kept too short to hit the lines, or that the wires are securely
anchored to the ground. If neither of these requirements can be
satisfied, a nonelectric system shall be used.
(q) In electrical firing, only the man making
leading wire connections shall fire the shot. All connections shall be made
from the bore hole back to the source of firing current, and the leading wires
shall remain shorted and not be connected to the blasting machine or other
source of current until the charge is to be fired.
(r) After firing an electric blast from a
blasting machine, the leading wires shall be immediately disconnected from the
machine and short-circuited.
40.9. Use of safety fuse.
(a) Safety fuse shall only be used where
sources of extraneous electricity make the use of electric blasting caps
dangerous. The use of a fuse that has been hammered or injured in any way shall
be forbidden.
(b) The handling of a
fuse on nails or other projections which will cause a sharp bend to be formed
in the fuse is prohibited.
(c) Before capping safety fuse, a short
length shall be cut from the end of the supply reel so as to assure a fresh cut
end in each blasting cap.
(d) Only
a cap crimper of approved design shall be used for attaching blasting caps to
safety fuse. Crimpers shall be kept in good repair and accessible for
use.
(e) No unused cap or short
capped fuse shall be placed in any hole to be blasted; such unused detonators
shall be removed from the working place and destroyed.
(f) No fuse shall be capped, or
primers made up, in any magazine or near any possible source of
ignition.
(g) No one shall be
permitted to carry detonators or primers of any kind on his
person.
(h) The minimum
length of safety fuse to be used in blasting shall be as required by state law,
but shall not be less than thirty (30) inches.
(i) At least two (2) men shall be present
when multiple cap and fuse blasting is done by hand lighting methods.
(j) Not more than twelve (12) fuses shall be
lighted by each blaster when hand lighting devices are used. However, when two
(2) or more safety fuses in a group are lighted as one (1) by means of igniter
cord, or other similar fuse-lighting devices, they may be considered as one (1)
fuse.
(k) The so-called "Drop Fuse"
method of dropping or pushing a primer or any explosive with a lighted
fuse attached is forbidden.
(l) Cap and fuse shall not be used for firing
mudcap charges unless charges are separated sufficiently to prevent one (1)
charge from dislodging other shots in the blast.
(m) When blasting with safety fuses,
consideration shall be given to the length and burning rate of the fuse.
Sufficient time, with a margin of safety, shall always be provided for the
blaster to reach a place of safety.
40.10. Use of detonating cord.
(a) Care shall be taken to select a
detonating cord consistent with the type and physical condition of the
bore hole and stemming and the type of explosives used.
(b) Detonating cord shall be handled and used
with the same respect and care given other explosives.
(c) The line of detonating cord
extending out of a bore hole or from a charge shall be cut from supply
spool before loading the remainder of the bore hole or placing additional
charges.
(d) Detonating cord shall
be handled and used with care to avoid damaging or severing the cord during and
after loading and hooking up.
(e)
Detonating cord connections shall be competent and positive in accordance with
approved and recommended methods. Knot-type or other cord-to-cord
connections shall be made only with detonating cord, in which the explosive
cord is dry.
(f) All detonating
cord trunk lines and branch lines shall be free of loops, sharp kinks, or
angles that direct the cord back toward the oncoming line of
detonation.
(g) All detonating cord
connections shall be inspected before firing the blast.
(h) When detonating cord
millisecond-delay connectors or short-interval-delay electric
blasting caps are used with detonating cord, the practice shall conform
strictly to the manufacturer's recommendations.
(i) When connecting a blasting cap or an
electric blasting cap to detonating cord, the cap shall be taped or otherwise
attached securely along the side or the end of the detonating
cord, with the end of the cap containing the explosive charge pointed in the
direction in which the detonation is to proceed.
(j) Detonators for firing the trunk line
shall not be brought to the loading area nor attached to the detonating cord
until everything else is in readiness for the blast.
40.11. Firing the blast.
(a) A code of blasting signals shall be
posted on one 91) or more conspicuous places at the operation, and all
employees shall be required to familiarize themselves with the code and conform
to it. Danger signs shall be placed at suitable locations.
(b) Before a blast is fired, a loud warning
signal shall be given by the certified blaster in charge, who has made certain
that all surplus explosives are in a safe place and all employees, vehicles,
and equipment are at a safe distance, or under sufficient cover.
(c) Flagmen shall be safely stationed on
highways which pass through the danger zone so as to stop traffic during
blasting operations.
(d) It
shall be the duty of the blaster to fix the time of blasting.
(e) Before firing an underground blast,
warning shall be given, and all possible entries into the blasting area, and
any entrances to any working place where a drift, raise, or other
opening is about to hole through, shall be carefully guarded. The blaster shall
make sure that all employees are out of the blast area before firing a blast.
U-1
Warning Signal - A 1-1 minute series of long blasts 5
minutes prior to blast signal.
Blast Signal - A series of short blasts 1 minute prior to
the shot.
All Clear Signal - A pro-
longed blast following the inspection of blast area.
40.12. Inspection after
blasting.
(a) Immediately after the blast has
been fired, the firing line shall be disconnected from the blasting
machine, or where power switches are used, they shall be locked open or in the
off position.
(b) Sufficient time
shall be allowed, not less than fifteen (15) minutes in tunnels, for the smoke
and fumes to leave the blasted area before returning to the shot. An
inspection of the area and the surrounding rubble shall be made by the
certified blaster to determine if all charges have been exploded before
employees are allowed to return to the operation, and in tunnels, after
the muck pile has been wetted down.
40.13. Misfires.
(a) If a misfire is found, the blaster shall
provide proper safeguards for excluding all employees from the danger
zone.
(b) No other work shall be
done except that necessary to remove the hazard of the misfire and only those
employees necessary to do the work shall remain in the danger zone.
(c) No attempt shall be made to extract
explosives from any charged or misfired hole; a new primer shall be put
in and the hole reblasted. If misfiring of the misfired hole presents a hazard,
the explosives may be removed by washing out with water, or, where the misfire
is under water, blown out with air.
(d) If there are any misfires while using cap
and fuse, all employees shall remain away from the charge for at least one (1)
hour. Misfires shall be handled under the direction of the person in charge of
the blasting. All wires shall be carefully traced and a search made for
unexploded charges.
(e) No
drilling, digging, or picking shall be permitted until all missed holes have
been detonated or the authorized representative has approved that work
can proceed.
40.14.
Definitions applicable to this subsection.
(a) "Approved Storage Facility" a facility
for the storage of explosive material conforming to the requirements of this
subpart and covered by a license or permit.
(b) "Blast Area" the area in which explosive
loading and blasting operations are being conducted.
(c) "Blaster" the person or persons
authorized to use explosives for blasting purposes and meeting the
qualifications in these rules and regulations.
(d) "Blasting Agent" a blasting agent is any
material or mixture consisting of a fuel and oxidizer used for blasting, but
not classified an explosive and in which none of the ingredients is
classified as an explosive provided the furnished (mixed) product
cannot be detonated with a No. 8 test blasting cap when confined. A common
blasting agent presently in use is a mixture of ammonia nitrate (NH4 N03) and
carbonaceous combustibles, such as fuel oil or coal, and may either be
procured, premixed and packaged from explosive companies or mixed in the
field.
(e) "Blasting Cap" a
metallic tube closed at one (1) end, containing a charge of one (1) or more
detonating compounds, and designed for and capable of detonation from the
sparks or flame from a safety fuse inserted and crimped into the open
end.
(f) "Block Holing" the
breaking of boulders or blasting agents by firing a charge of explosives that
has been loaded in a drill hole.
(g) "Conveyance" any unit for
transporting explosives or blasting agents, including but not limited
to trucks, trailers, rail cars, barges and vessels.
(h) "Detonating Cord" a flexible cord
containing a center core of high explosives which when detonated, will have
sufficient strength to detonate other cap-sensitive explosives with
which it is in contact.
(i)
"Detonator" blasting caps, electric blasting caps, delay electric blasting
caps, and nonelectric delay blasting caps.
(j) "Electric Blasting Cap" a blasting cap
designed for and capable of detonation by means of an electric
current.
(k) "Electric Blasting
Circuitry"
(1) Bus wire. An expandable wire,
used in parallel or series, in parallel circuits, to which are connected the
leg wires of electric blasting caps.
(2) Connecting wire. An insulated
expendable wire used between electric blasting caps and the leading wires or
between the bus wire and the leading wires.
(3) Leading wire. An insulated wire used
between the electric power source and the electric blasting cap
circuit.
(4) Permanent blasting
wire. A permanently mounted insulated wire used between the electric power
source and the electric blasting circuit.
(l) "Electric Delay Blasting Caps" caps
designed to detonate at a predetermined period of time after energy is applied
to the ignition system.
(m)
"Explosives"
(1) Any chemical compound,
mixture, or device, the primary or common purpose of which is to function by
explosion; that is, with substantially instantaneous release of gas and
heat.
(2) All material which is
classified as Class A, Class B, and Class C explosives by the West
Virginia department of mines.
(3)
Classification of explosives by the West Virginia department of mines is as
follows:
Class A explosives. Possessing detonating hazard, such as
dynamite, nitroglycerin, picric acid, lead azide, fulminate of mercury,
black powder, blasting caps, and detonating primers.
Class B explosives. Possessing flammable hazard, such as
propellent explosives, including some smokeless propellants.
Class C explosives. Include certain types of manufactured
articles which contain Class A or Class B explosives, or both, as components,
but in restricted quantities.
(n) "Fuse Lighters" special devices for the
purpose of igniting safety fuse.
(o) "Magazine" any building or
structure, other than an explosives manufacturing building, used for
the storage of explosives.
(p)
"Misfire" an explosive charge which failed to detonate.
(q) "Mud-capping" (sometimes known as
bulldozing, adobe blasting, or adobying). The blasting of boulders by
placing a quantity of explosives in a drill hole.
(r) "Nonelectric Delay Blasting Cap" a
blasting cap with an integral delay element in conjunction with and capable of
being detonated by a detonation impulse or signal from miniaturized
detonating cord.
(s) Primary
Blasting" the blasting operation by which the original rock formation is
dislodged from its natural location.
(t) "Primer" a cartridge or container of
explosives into which a detonator or detonating cord is inserted or
attached.
(u) "Safety Fuse" a
flexible cord containing an integral burning medium by which fire is conveyed
at a continuous and uniform rate for the purpose of firing blasting
caps.
(v) "Secondary Blasting" the
reduction of oversize material by the use of explosives to the dimension
required for handling, including mud-capping and blockholding.
(w) "Stemming" a suitable inert
incombustible material or device used to confine or separate explosives
in a drill hole, or to cover explosives in mud-capping.
(x) "Springing" the creation of a pocket in
the bottom of a drill hole by the use of a moderate quantity of explosives in
order that larger quantities of explosives may be inserted therein.
(y) "Water Gels, or Slurry Explosives" a wide
variety of materials used for blasting. They all contain substantial
proportions of water and high proporations of ammonium nitrate, some of which
is in solution in the water.
Two (2) broad classes of water gels are:
(1) those which are sensitized by a material
classed as a explosive, such as TNT or smokeless powder; and
(2) those which contain no ingredient
classified as an explosive; these are sensitized with metals such as aluminum
or with other fuels. Water gels may be premixed at an explosive plant or mixed
at the site immediately before delivery into the bore hole.