020-3 Wyo. Code R. §§ 3-6 - Emission Standards for Volatile Organic Compounds
(a)
The term "volatile organic compounds" (VOCs) is
defined in 40 CFR Part 51.100(s), 51.100(s)(1), and 51.100(s)(5), incorporated
by reference under Section 9(a) of this chapter.
(b) VOC emissions shall be limited through
the application of Best Available Control Technology (BACT) in accordance with
Chapter 6, Section 2 of these regulations. Notwithstanding the above, whenever
acceptable control of VOC emissions from vapor blowdown, emergency relief
systems, or VOC emissions generated from oil and gas production, storage,
exploration, development, or processing operations is specified pursuant to
these regulations as a flare, the flare shall not exceed a 20 percent opacity
emission standard. If acceptable control of VOC emissions is specified as a
smokeless flare, the definition given in subsection (i) of this section
applies.
(i) For the purposes of this section,
"smokeless flare" means a flare designed for and
operated with no visible emissions except for periods not to exceed a total of
5 minutes during any 2 consecutive hours.
(ii) Each flare subject to Chapter 3, Section
6(b) must be equipped and operated with an automatic igniter or a continuous
burning pilot which must be maintained in good working order.