041-2 Wyo. Code R. §§ 2-12 - Clearance Sampling
(a) Clearance
sampling shall be performed in the same manner as assessment sampling as
qualified in this section.
(b) HVAC
system clearance shall be performed by collecting Target Compound wipe samples
from the furnace, one supply duct and one return duct if present. Sample
locations in ductwork shall be randomly selected from areas that are not
reachable from existing openings such as vents. Fresh openings for sampling
shall be made using tin snips or other cutting means.
(c) Sample locations of the structure and any
remediated movable items shall be randomly selected.
(d) Any repeat clearance sampling shall
include locations that indicated failure as well as additional locations that
were not previously sampled.
(e) If
clearance sample data indicates that some part(s) of a structure are in
compliance with the AL (or AL-LAA as applicable) and some are not, the
following procedures may be used:
1) The
whole structure may be re-cleaned and entirely re-tested.
2) The rooms or areas where clearance data
indicates compliance may be sealed off from the rest of the structure, provided
that egress during remediation does not require any re-entry to those areas,
and the non-compliant areas may be re-cleaned and re-tested.