020-6 Wyo. Code R. § 6-5 - Records of Blasting Operations
(a) A record of
each blast, including seismograph reports, shall be retained for at least three
years and shall be available for inspection by the Administrator and the public
on request. The record shall contain the following data:
(i) Name of permittee, operator, or other
person conducting the blast;
(ii)
Location, date and time of blast;
(iii) Name, signature, and certification
number of blaster conducting the blast;
(iv) Identification, direction and distance,
in feet, from the nearest blast hole to the nearest dwelling, public building,
school, church, and community or institutional building outside the permit area
neither owned nor leased by the permittee;
(v) Weather condition;
(vi) Type of material blasted;
(vii) Sketches of the blast pattern including
number of holes, burden, spacing, decks and delay pattern;
(viii) Diameter and depth of holes;
(ix) Types of explosives used;
(x) Total weight of explosives used per
hole;
(xi) Maximum weight of
explosives detonated within any eight millisecond period;
(xii) Initiation system;
(xiii) Type and length of stemming;
(xiv) Mats or other protections
used;
(xv) Seismograph and airblast
records, where required, including:
(A) Type
of instrument, sensitivity, and calibration signal or certification of annual
calibration;
(B) Exact location of
instrument and the date, time, and distance from the blast;
(C) Name of person and firm taking the
seismograph reading;
(D) Name of
person and firm analyzing the seismograph record; and
(E) The vibration and/or airblast level
recorded,
(xvi) Reasons
and conditions for each unscheduled blast.