Cal. Code Regs. Tit. 8, § 3066 - Capacity and Loading
(a) Applicable
Requirements. The requirements of Section
3037 covering capacity and loading
shall apply to hydraulic elevators except for the following:
(1) With Class C2 loading, all parts of the
hydraulic equipment shall be designed for the maximum pressure developed in the
system during loading and unloading.
(2) The crosshead data plate or plates shall
indicate the following:
(A) The weight of the
complete car and the auxiliary equipment attached to the car, excluding the
plunger and cylinder where they are not part of the car frame.
(B) The rated load and speed.
(C) The outside diameter and wall thickness
of the finished plunger.
(D) The
manufacturer's name and date of installation.
(3) The requirements of Section
3037(g) for
lifting one-piece loads do not apply. Hydraulic elevators shall not be loaded
to exceed their rated load as specified on the capacity plate unless designed
and installed to carry one-piece loads exceeding their rated load.
(4) The requirements of Design Section
3100(b),
Additional Requirements for Passenger Overload, do not apply to hydroelectric
elevators.
Notes
2. New NOTE filed 12-8-86; effective thirtieth day thereafter (Register 86. No. 50).
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
2. New NOTE filed 12-8-86; effective thirtieth day thereafter (Register 86. No. 50).
Group II regulations apply to existing elevators installed prior to October 25, 1998. Italicized paragraphs, sentences, or phrases apply to all existing elevators while non-italicized apply to elevators installed after 1970 or after the date the regulation was adopted.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.