Cal. Code Regs. Tit. 8, § 3286 - Manual Boatswain's Chairs and Controlled Descent Apparatus (CDA)
(a) Use and
Application.
(1)
(A) Boatswain's chairs and CDAs shall be used
for window cleaning operations only where the windows cannot be cleaned safely
and practicably by other means.
(B)
When boatswain's chairs or CDAs are used for window cleaning operations, the
following conditions shall be complied with:
1. Manual boatswain's chairs shall not be
used where the height of suspension exceeds 75 feet or unless otherwise
accepted by the Division where the heights exceed 75 feet.
2. CDAs shall not be used where the height of
suspension exceeds 130 feet or unless otherwise accepted by the Division in
writing when the height exceeds 130 feet.
3. Roof tie-backs or other approved
independent anchorages shall be provided for each support line(s) and each
safety line.
4. Each support
line(s) and each safety line shall be connected to approved independent
anchorages.
5. An Operating
Procedures Outline Sheet (OPOS) shall be developed as required in Section
3282(p)(1)(C).
(2)
(A)
Employees shall be trained in the use of boatswain's chairs and/or CDAs before
they shall be permitted to use such equipment.
(B) Training shall include, but not be
limited to, proper rigging of support lines, inspection of primary support
line(s) and safety lines and anchorage, safe use of CDAs or boatswain's chairs,
fall arrest systems, and self rescue methods.
(3) When a boatswain's chair or CDA is
suspended over an area traversed by workers, pedestrians or vehicular traffic,
the ground area below and within the window cleaner's work zone shall be
effectively blocked by barricades, or an attendant shall be stationed to keep
the area clear. Warning signs shall also be posted below.
(4) Employees using boatswain's chairs or
CDAs shall be provided, and instructed in the use of, a personal fall arrest
system meeting the requirements of Article 6, Appendix C, Section I of the
General Industry Safety Orders, and as otherwise provided by these orders. Each
employee's fall arrest system shall be secured to an independent safety line
attached to an approved anchorage.
(b) Rigging, Block and Tackle.
(1) Rope attachment to a block shall be by a
thimble and splice.
(2) A safety
hook or shackle shall be used on the upper block to prevent accidental
disengagement.
(3) Each double
block of luff (or watch) tackle shall be branded or otherwise clearly marked so
as to indicate the fully extended length in feet from block to block.
(4) Where the chair connects to the block and
tackle, a safety hook shall be used to prevent accidental rope
disengagement.
(5) Tackle shall
consist of rope equivalent in strength to 5,400 pounds. Blocks shall be
compatible with the suspension rope diameter.
(6) Parapet or cornice hooks shall be
provided with tie-back rings. Each parapet or cornice hook shall be tied back
with wire rope to a roof tie-back or equivalent anchorage.
(c) Specifications.
(1)
(A)
Boatswain's Chair. The chair shall be suspended from its four corners by means
of rope slings. It shall have a seat not less than 24 inches long by 10 inches
wide and, if of soft wood, 2 inches thick (1 1/8 inches if of oak or ash). It
shall be reinforced across the full width by cleats securely fastened to each
end. A rope or strap guard across the front and rear approximately 18 inches
above the seat shall be provided. The seat may be constructed of material other
than wood, provided the material is equivalent in strength to 2 inches of soft
wood or 1 1/8 inches of oak or ash. If constructed of material of equivalent
strength, cleats across the full width of the seat shall be provided unless
structural analysis indicated they are not necessary. Other design and
construction may be substituted if it can be shown to provide equal safety and
strength.
(B) Boatswain's chairs,
their supports and all accessories shall be capable of supporting, without
failure, 4 times the maximum load that may be placed thereon.
NOTE: See Section 3286(b)(1).
(C) Buckets used in boatswain's chair work
shall be attached in such a manner that the buckets will not
fall.
(2) CDA Seatboards.
(A) Seatboards shall be made of wood or other
suitable materials, and may be reinforced. Seatboards shall be capable of
supporting a live load of at least 250 pounds. All rope and webbing used in
suspending the seatboard to a CDA shall be of synthetic fiber, preferably nylon
or polyester, that has a rated minimum strength of 5000 pounds.
(B) Buckets used in seatboard work shall be
attached in such a manner that they will not
fall.
(d)
Controlled Descent Apparatus (CDA)
(1)
(A) CDA system shall include but not be
limited to the following:
1. Working
line(s);
2. Controlled descent
device;
3. Seatboard;
4. Personal fall arrest system;
5. Independent safety line
(lifeline);
6. Locking carbineer
(D-ring).
NOTE: For the purpose of Section 3286 a full body harness is required as part of the personal fall arrest system.
(B) The controlled descent device and
seatboard shall be permanently marked with:
1. Manufacturer's or Trade name,
and
2. Model number, and
3. Identification (serial) number,
and
4. Date of
manufacture.
(C) Working
lines and safety lines shall be permanently marked or tagged with:
1. Manufacturer's name, and
2. Length/size, and
3. Date of manufacture, and
4. Date placed in
service.
(D) Personal
fall arrest systems shall comply with the requirements in Article 6, Appendix C
of the General Industry Safety Orders.
(2) The working line(s) shall be the proper
size to pass over and/or around the fixed members of the controlled descent
device body as recommended by the device manufacturer.
(3) Working lines, safety lines, and lanyards
shall have spliced or swaged ends as per the rope manufacturer's
specifications.
(4) Lanyards shall
not exceed 4 feet in length.
(5)
Knots shall not be permitted at ends or anywhere along the length of lanyards,
working lines or safety lines.
(6)
Descent control devices shall be used in accordance with the manufacturer's
instructions. Employees shall not be permitted to use descent control devices
unless these devices are specifically designed for building maintenance or
window cleaning operations.
(7) The
entire CDA system shall be visually inspected before and during each use. If
any part of the system shows excessive wear, damage or deformation, that part
shall be removed from service and discarded.
(8)
(A)
Safety lines and lanyards shall be removed from service as recommended by the
manufacturer or if one of the following conditions is evident or occurs:
1. Braids or webbing are cut, or
2. Excessive abrasion or worn fibers,
or
3. There is hardness or
stiffness, or
4. Dirt or grit has
clogged fibers, or
5. Rust, tar or
grease is present, or
6. Line size
has been reduced, or
7. Safety
lines and lanyards are subjected to a shock load, or
8. Safety lines and lanyards are exposed to
chemicals that affect their strength, or
9. Safety lines and lanyards are exposed to
excessive ultra violet degradation.
(B) Working lines shall not be used longer
than two (2) years from date first placed in service or three (3) years from
date of manufacture.
(9)
All descent control devices shall be 100% proof load tested at 3600 pounds
without visual evidence of cracking, breaking or permanent
deformation.
(10) Chemicals having
adverse effects on the CDA system, as determined by the chemical or equipment
manufacturer, shall not be used for window cleaning.
(11) Any working or safety line that passes
over any edge of a building or structure or passes over any sharp object shall
be protected from cutting and/or abrasion.
(12) Working lines that have been used to
stop a CDA's free fall of four feet or more in distance shall be removed from
service.
(13) Working lines that
have been subjected to a rapid descent by an employee using the CDA shall be
removed from service.
(14) Prior to
making a drop, the building exterior shall be visually inspected and, where
necessary, appropriate measures taken to ensure that building features, such as
sharp edges of parapets and window frames cannot impair the structural
integrity of the CDA system or associated fall protection rigging.
(15) A safe means of access, which includes
the use of a personal fall arrest system, shall be provided before employees
gain access to and egress from CDA drop locations.
Notes
2. Amendment of subsection (a)(4) and (b)(1) and (5) filed 9-12-85; effective thirtieth day thereafter (Register 85, No. 37).
3. Amendment of subsections (a)(3), (a)(4) and (c)(1) filed 3-9-93; operative 4-8-93 (Register 93, No. 11).
4. Amendment of section heading and section filed 7-23-98; operative 8-22-98 (Register 98, No. 30).
5. Amendment of subsection (a)(4) filed 3-31-2000; operative 4-30-2000 (Register 2000, No. 13).
Note: Authority cited: Section 142.3, Labor Code. Reference: Section 142.3, Labor Code.
2. Amendment of subsection (a)(4) and (b)(1) and (5) filed 9-12-85; effective thirtieth day thereafter (Register 85, No. 37).
3. Amendment of subsections (a)(3), (a)(4) and (c)(1) filed 3-9-93; operative 4-8-93 (Register 93, No. 11).
4. Amendment of section heading and section filed 7-23-98; operative 8-22-98 (Register 98, No. 30).
5. Amendment of subsection (a)(4) filed 3-31-2000; operative 4-30-2000 (Register 2000, No. 13).
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.