Cal. Code Regs. Tit. 8, § 7000 - Working Space for Machine Operators
(a)
Unobstructed working space shall be provided at the operating controls of every
fixed machine. Such working space shall be at least 3 feet wide, and long
enough to provide access to all operating controls.
(b) Adequate unobstructed working space shall
be provided at the operating controls of every movable machine.
Such unobstructed working space shall be at least 3 feet wide and 6 ½ feet in height, except when the operator works in a sitting position, in which case he shall be provided with an overhead clearance of at least 2 feet.
(c)
Where the operating controls are located at the side of the machine, at least 2
feet of unobstructed space shall be maintained between the operating controls
and the nearest wall or object while the machine is in operation.
(d) Boom and rocker-type mucking machines
shall be equipped with a substantial device to keep them from
upsetting.