310 CMR, § 15.262 - Greywater Systems
(1) Greywater from
residential, commercial and public facilities may be discharged or reused in
accordance with the provisions of 310 CMR 15.262. For purposes of 310 CMR
15.262, public facilities shall include facilities owned or operated by a local
political subdivision of the Commonwealth or an agency of the Commonwealth or
federal government.
(2)
Soil Absorption System for Greywater. When the total
discharge to an on-site subsurface sewage disposal consists entirely of
greywater as defined in
310 CMR 15.002
(Greywater), the following shall apply:
(a)
the minimum soil absorption area for residential systems, as determined by the
results of the site evaluation set forth in
310 CMR 15.100
through
15.107
and in accordance with the appropriate long-term acceptance rate criteria
specified in
310 CMR
15.242, for design of a soil absorption
system for new construction of a facility, or for upgrades to existing systems
may be reduced by no more than 50%, provided, however, that for new
construction, the owners of residential facilities shall demonstrate that a
system in full compliance with
310 CMR 15.000 can be
installed on the facility to serve the proposed design flow. Reductions for
commercial and public facility systems shall be determined on a case-by-case
basis as approved by the Department in accordance with
310 CMR
15.203(6).
(b) the depth of soil placed as backfill over
the system shall be at least nine inches, placed in lifts and sufficiently
compacted to prevent depression due to settling which may intercept surface
runoff above the system. Backfill must be clean and free of stones greater than
two inches in size. Tailings, clay, or similar material is
prohibited.
(c) in a remedial
upgrade of an existing system with no increase in flow, the required separation
between the bottom of the soil absorption system and the high groundwater
elevation may be reduced to a minimum of two feet in soils with a recorded
percolation rate of more than two minutes per inch or a minimum of three feet
in soils with a recorded percolation rate of two minutes or less per
inch.
(3)
Septic Tanks or Filter for a Greywater System.
Greywater systems may include either a septic tank or a filter, provided the
filter has been approved by the Board of State Examiners of Plumbers and Gas
Fitters and/or the Department in accordance with
310
CMR 15.289(1)(b).
(a) The septic tank shall have a minimum
effective liquid capacity of 1000 gallons and shall be designed in accordance
with 310 CMR 15.223 through
15.226.
(b) Septic tanks for commercial and public
facilities shall be at least b the size of a septic tank based on the design
flows presented in
310
CMR 15.203.
(c) When
310
CMR 15.203 does not provide design flows the
design flow shall be based on historical flows (one year or more) of the
facility or similar facilities if historical flows are not available and shall
be 200% of average water meter readings or 125% of the recorded peak flow,
whichever is greater.
(4) Greywater may be discharged using an
alternative to a soil absorption system approved by the Department pursuant to
310
CMR 15.280 through
15.288.
(5) Greywater from commercial or public
facilities may be approved by the Department on a case-by-case basis for reuse
in accordance with
314 CMR
20.00: Reclaimed Water Permit Program and
Standards, and applicable policies and guidance of the Department
pertaining to wastewater reuse.
(6)
Greywater systems shall be operated, maintained, and inspected in accordance
with 310 CMR 15.300.
(7) For residential facilities utilizing
composting toilets and greywater systems in nitrogen sensitive areas an
allowable loading rate of 660 gpd/acre may be used provided that there is no
discharge of blackwater at the facility and the compost is disposed off-site.
Annual inspections shall be conducted in accordance with
310
CMR 15.300(5).
(8) For commercial and public facilities
utilizing composting toilets and greywater systems in nitrogen sensitive areas,
an allowable loading rate up to 770 gpd/acre shall be determined by the
Department on a case-by-case basis provided that there is no discharge of
blackwater at the facility and the compost is disposed off-site. Annual
inspections shall be conducted in accordance with
310
CMR 15.300(5).
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.